Tasmota script for Siemens TD-3511 SmartMeter
This commit is contained in:
commit
c3c47c3412
41
README.md
Normal file
41
README.md
Normal file
@ -0,0 +1,41 @@
|
||||
# Tasmota (Siemens TD-3511)
|
||||
```
|
||||
>D
|
||||
scnt=0
|
||||
res=0
|
||||
|
||||
>B
|
||||
=>sensor53 r
|
||||
|
||||
>F
|
||||
; count 100ms
|
||||
scnt+=1
|
||||
switch scnt
|
||||
|
||||
;300ms after start: set sml driver to 300 baud and send /?! as HEX to trigger the Meter
|
||||
case 3
|
||||
res=sml(1 0 300)
|
||||
res=sml(1 1 "2F3F210D0A")
|
||||
|
||||
;1700ms later: Ack and ask for switching to 9600 baud
|
||||
case 20
|
||||
res=sml(1 1 "063035300D0A")
|
||||
|
||||
;300ms later: switch sml driver to 9600 baud
|
||||
case 23
|
||||
res=sml(1 0 9600)
|
||||
|
||||
;5000ms after start: Restart sequence
|
||||
case 50
|
||||
scnt=0
|
||||
|
||||
ends
|
||||
>M 1
|
||||
+1,5,o,0,9600,TD3511,4
|
||||
1,1.8.1(@1,Total In,KWh,Total_in,3
|
||||
1,1.7.0(@0.001,Power In,W,power_in,0
|
||||
1,31.7(@1,Strom L1,A,I_L1,2
|
||||
1,51.7(@1,Strom L2,A,I_L2,2
|
||||
1,71.7(@1,Strom L3,A,I_L3,2
|
||||
#
|
||||
```
|
||||